*** TURBOSOUND MANCHESTER Series ***
***       V1.0 RELEASE           ***
____________________________________________________
LAB GRUPPEN PLM12K44/PLM20K44 & D SERIES L DSP AMPLIFIERS ONLY - LM SERIES PROCESSORS ARE NOT SUITABLE

MV212 3W 80 Hz module for use with MS215 & MS218 subs
Pre-aligned for use with "MS215 80Hz", "MS215 80Hz CARDIO", "MS218 80Hz" & "MS218 80Hz CARDIO" Modules

OUTPUTS: MANDATORY TO HAVE MODULE OUTPUT MIXING (MOM) ENABLED IN LAKE SOFTWARE
USER TO ASIGN CORRECT OUTPUT PATCHING COMBINING MID & HIGH DSP OUTPUTS INTO THE SAME AMPLIFIER INPUT
SEE QSG FOR INSTRUCTION - FAILURE TO USE MOM WILL DEGRADE ARRAY PERFORMANCE AND FREQUENCY RESPONSE
**SELECT MF FIRST THEN HF TO MIX MODULE OUTPUTS: EXAMPLE PATCH LF= OUTPUT 1, MF OUTPUT 2, HF OUTPUT 2 or
LF= OUTPUT 3, MF OUTPUT 4, HF OUTPUT 4**

ISVPL profile should be set to Sub/LF for 12" LF and universal for MF & HF
___________________________________________________

EQ OVERLAYS:

SEE SEPARATE "Array Size Comp" & "Distance EQ" Folders 
FOR ARRAY OPTIMISATION OF LINE LENGHT AND DISTANCE EQ (ZONAL/THROW HF CONTROL)

Notes:
 
1) do not insert more than one Array Size Compensation overlay at the same time, 
whole array should have same overlay inserted

2) each ZONE of elements within the Array uses the nearest DISTANCE EQ (AirEQ) overlay 

____________________________________________________

Application Notes:

GAIN: all modules assume 35 dB amplifier gain
(for PLM / D series L this is already set and locked)

WARNING: Ensure correct routing before use Module Output Mixing IS MANDATORY!
____________________________________________________      

Please read the MANCHESTER QSG and Rigging Manual prior to use 

*** Designed by Music Tribe - 12 SEPT 2019 ***
http://www.turbosound.com
https://www.turbosound.com/brand/turbosound/support#googtrans(en|en)